Capacity
- Compressor (HP) 20 or more
- Cooling capacity (Refrigeration tons) 15 or more
Compressor Options Semi Hermetic Compressor (WCS)
- Semi-hermetic reciprocating compressor
- Suction gas cooled motor
- Suction and discharge stop valve
- Step capacity control
- Crankcase heater with current sensing relay
- Suction and discharge pressure transmitter
- High pressure switch
- Hot gas capacity control
Open Type Compressor (WCO)
- Suction and discharge stop valve
- Step capacity control
- Drive coupling and C-flange adaptor/coupling guard
- Suction and discharge pressure transmitter
- Discharge high temperature cut-out
- High pressure switch
- Oil flow switch
- Oil separator
- TEFC motor certified for hazardous environments
- Hot gas capacity control
Scroll Compressor (WCZ)
- Suction gas cooled motor
- Suction and discharge stop valve
- High pressure switch
- Crankcase heater with current sensing relay
- Hot gas capacity control
Screw Compressor (WCQ)
- Suction gas cooled motor
- Suction and discharge stop valve
- Slide valve capacity control
- Integral oil separator with heater and current sensing relay
- Crankcase heater with current sensing relay
- Suction and discharge pressure transmitter
- High pressure switch
- Hot gas capacity control
Evaporator
- High efficiency copper brazed stainless steel plate construction
- Designed and constructed in accordance with ASME code
Or
- High efficiency shell and tube construction
- Carbon steel shell (water side)
- Copper tube with inner fin (refrigerant side)
- Vessel designed and constructed in accordance with ASME code
Other materials of construction are available upon request.
Chiller Vessel
- High efficiency shell and tube construction
- Coded vessel steel shell on water side
- Copper tube with inner fin on refrigerant side
Water-Cooled Condenser
- Heavy construction while maintaining maximum heat transfer
- Steel shell on refrigerant side
- Copper tubing with outer fin on water side
- Removable heads for cleaning
Frame
- Frame manufactured from heavy gauge structured steel tube with welded construction.
Safety Controls
Tested under load conditions prior to shipment All safety controls are factory set and checked
- Freeze-up controls
- High and low refrigerant pressure controls
- Compressor motor overload protection
- Tank low-level cutout (glycol units)
- Oil pressure safety control
- Refrigerant pressure relief valve
Electrical
- 460 / 575 / 230 / 380 Volts 60 / 50 Hz
- 120 / 240 Volt single phase control voltage
- Microprocessor controller
- Operating and fail lights
- UL or CSA approved components
Central Control Electrical Panel
A custom electrical control panel allows one point hookup and may include:
- HMI ( Human Interface Device ) touchscreens
- PLC ( Programable Logic Control )
- SCADA ( Supervisory Control And Data Acquisition ) Communication Systems
- 24/7 alarm reporting to cell phones
All pump starters, fuses, disconnect, control voltage transformer, run and fail lights, are housed in a common NEMA rated panel.
Central Thermostat Control System
This system is used to control chiller units in a multiple central industrial chilling system. The temperature controller is located at the Berg tank and senses the process water temperature. The process water temperature is maintained by cycling the chiller units.